Counterfeiting Kills

Each year, the counterfeiting of well-known brands and products continues to rise, creating an even more threatening problem. Such well-known counterfeited brands, including consumer safety and critical electrical products, are estimated to be five to seven percent of world trade. The International Anti-Counterfeiting Coalition (IACC) estimates that the counterfeiting of distinguished brands costs industries $600 billion each year worldwide and may result in as many as 750,000 lost jobs every year in the United States.

...

Buyer's Guide


News & Trends



Introducing Intelligent Power Today

Welcome to Intelligent Power Today Magazine, our publication that explores and explains the who, what, where, when, why and how of intelligent electrical devices, a collection of complex mechanical devices and sophisticated control systems used in industrial, commercial, and institutional...

Electrical Safety

voltage testing

Absence of Voltage Testing – An Update on Accepted Approaches

Absence of voltage testing is a vital step in the process of verifying and establishing a de-energized state of any electrical system. As detailed in NFPA 70E clause 4.2.5., there is a specific and approved approach to establishing an electrical safe work condition with the following steps:

  • determine all possible source of electrical supply
  • interrupt the load current, open the disconnecting device for each possible source
  • verify where possible that all blades of the disconnecting devices are open
  • release or block any stored energy
  • apply lockout device in accordance with documented and established work procedures
  • using an adequately rated portable...

The Guide to Arc Flash Clothing

A new method to choosing personal protective equipment

BY JIM WHITE, Shermco Industries, Inc.

Table 130.7(C)(15)(a) in the 2012 edition of NFPA 70E: “Standard for Electrical Safety in the Workplace”, published by the National Fire Protection Association, has always been difficult for technicians and safety professionals to use in the field. Even though it has an outstanding record since being introduced in the 2000 edition of NFPA 70E, some members of the technical committee have been solidly against it.

One of those committee members stated that if the tables were eliminated, everyone would be forced to have an incident...

Popular Electrical Safety Articles


Calculating Incident Energy

Over the last few decades, arc-fl ash hazards have been a significant concern for many electrical workers and employers. Many methods have been developed through the years to assess incident energy.The most common is that of the IEEE 1584, Guide for Performing Arc-Flash Hazard Calculations. These...

Underestimating Arc Flash Hazards

While most discussions about arc flash involve the calculation methods and associated personal protective equipment (PPE), electricians have a number of ways to protect themselves and their gear, including arc-resistant equipment and remote actuation and racking systems that eliminate—rather than...

How to Improve Electrical Safety

Avoid hazards with these suggestions BY ROB PROSSER & DANIELLE GALLO, Brady With an increase in accidents and injuries occurring in a variety of industries, employers are looking for ways to reduce hazards and improve safety within their facilities. Even with a plethora of information available...

Arc Flash Safety for Data Centers

15 arc flash mitigation strategies for the data center BY DAVID G. LOUCKS, Eaton Corporation Arc flashes—the fiery explosions that can result from short circuits in high-power electrical devices—kill hundreds of workers in the U.S. every year and permanently injure thousands more. They can also...