Power Quality & Grounding
How to Protect Data Centers
Electrical Grounding and the Weather
Power Quality & Grounding

INSULATION RESISTANCE TEST
Insulation Resistance (IR) test, often called Megger test, is more than 100 years old and assumed to be a very straightforward test. During my inspection and testing work in the past 15 years in Canada, US, and internationally, I have seen different practices of performing and interpretation of IR test.
The application of IR test includes:
At the point of installation, pre-commissioning to ensure minimum specifications are met
- Verify proper installation after a repair
- Troubleshooting
- ...
Related Articles

Electrical Grounding and the Weather
How resistance testing is affected by the elements BY JEFF JOWETT, Megger Ground resistance testing is affected by the weather as much as any common electrical test—and sometimes even more so. Both the instrument and the test item are affected. With ground resistance testing, the test item is not...

Compatibility Issues with Generator-Backed Power Systems
Line-interactive uninterruptible power supply (UPS) systems play a vital role in maintaining seamless operation during power outages. Their integration with backup generators, however, can pose challenges regarding synchronization and power quality. While both UPS systems and generators serve as...

Solving Power Quality Troubles in VFDs
Q: What are some of the negative power quality impacts from voltage variances and transients on variable frequency drives (VFDs)? And, what are some recommended solutions to resolve this VFD site issue? OUR EXPERT | Paul Wright, P.Eng, engineered drive solutions manager, Electrical Controls...

How to improve your NEC/CSA Installations
Grounding and Bonding are the least understood, the most misinterpreted and confusing elements in modern electrical and electronic systems and leads to poor design and installation work — especially as it relates to the Canadian Electrical Code (CEC) and to the National Electrical Code (NEC)...

Compatibility Issues with Generator-Backed Power Systems
Line-interactive uninterruptible power supply (UPS) systems play a vital role in maintaining seamless operation during power outages. Their integration with backup generators, however, can pose challenges regarding synchronization and power quality. While both UPS systems and generators serve as...

How to improve your NEC/CSA Installations
Grounding and Bonding are the least understood, the most misinterpreted and confusing elements in modern electrical and electronic systems and leads to poor design and installation work — especially as it relates to the Canadian Electrical Code (CEC) and to the National Electrical Code (NEC)...

INSULATION RESISTANCE TEST
Insulation Resistance (IR) test, often called Megger test, is more than 100 years old and assumed to be a very straightforward test. During my inspection and testing work in the past 15 years in Canada, US, and internationally, I have seen different practices of performing and interpretation of IR...

Power Usage Effectiveness in Data Centers
Guidance for calculation of efficiency in data centers BY VICTOR AVELAR, Schneider Electric The benefits of determining data center infrastructure efficiency as part of an effective energy management plan are widely recognized. The standard metrics of power usage effectiveness (PUE) and its...

The Art of Ground Testing
Correcting the misconceptions of ground testing BY JEFF JOWETT, Megger Ground resistance testing is sometimes described as an “art”, and indeed something can be said for that description. Familiarity with the basic issues and common problems, however, can take much of the “art” out of it...

Reducing Electrical Risks in Data Centers
Industrial-strength solutions to improve safety BY MIETEK GLINKOWSKI, ABB A major source of disruption and downtime in data centers is human error. And their largest safety hazard is in the increasing size of the electrical systems that power them. Both of these risks can be addressed at two...